This information is provided for information only. The applicable specification is included in each Gas Transportation Agreement, Connection Agreement or other agreement between EGP and its counterparties.
Item |
Specification |
Test Method |
Minimum Temperature |
2°C |
|
Maximum Temperature |
50°C |
|
Wobbe Index |
Minimum 46.0 |
ISO 6976; |
Oxygen |
Maximum 0.2% by volume |
ISO 6974 and ISO 6975; |
Total Inerts |
Maximum 7% by volume |
ISO 6974 and ISO 6975; |
Hydrocarbon Dew Point |
Maximum 2°C |
|
Water Content |
Minimum water dew point of 0°C at MAOP. This is equivalent to a maximum water content of 75 mg/m3 at 14,895 kPa and 70 mg/m33 at 16,550 kPa. Note: the m3 is at standard conditions |
ASTM D1142 |
Hydrogen Sulphide |
Maximum 5.7 mg/m3 |
ISO 6326 |
Total Sulphur (including odourant) |
Maximum 50 mg/m3 |
ASTM D1072 |
Total Sulphur (excluding odourant) |
Maximum 40 mg/m3 |
ASTM D1072 |
Jemena undertakes to maintain the operating pressure on the Eastern Gas Pipeline between 3,000 kPa gauge and 16,550 kPa gauge.